Product Highlights
Operating System Network ApplianceT Data ONTAPT
Standard Software Features FlexVolT, integrated automatic RAID manager, SnapshotT, Fast Boot, e-mail alerts, NIS, DNS, SNMP, FilerView®, NDMP, LDAP
Network Protocol Support Microsoft® CIFS, NFS V2/V3/V4 over UDP or TCP, HTTP 1.0, HTTP 1.1 virtual hosts, FTP
SAN Protocol Support FCP; iSCSI; fabric-attached and direct-attached
Licensed Software Products FlexCloneT, MultiStoreT, Clustered Failover, SnapMirror®, SnapRestore®, SnapDriveT, SnapManager® for Microsoft Exchange, SnapManager for Microsoft SQL Server, SnapVaultT, LockVaultT, SnapLockT Compliance, SnapLockT Enterprise, SyncMirrorT, MetroCluster, DataFabric® Manager, ApplianceWatchT for HP Openview, Tivoli
Hardware Features Full-duplex 10/100/1000 Base-T Ethernet onboard, Fibre Channel ports onboard, Remote LAN Management Module (optional),(1) Built-in LVD SCSI Port, diagnostic LED/LCD, Compact Flash redundant hot-plug cooling fans, redundant hot-plug power supplies, 19" rack-mount enclosure, optional 220V 42U 19" system cabinet
Default (Max.) RAID Group Sizes RAID-4 (Single Parity) - FC-Data/Parity: 7+1 (13+1); SATA- Data/Parity: 7+1 (7+1)

RAID-DP (Dual-parity) - FC-Data/Parity: 14+2 (26+2); SATA- Data/Parity: 12+2 (14+2)
Disk Shelves Supported (Fibre Channel) DS14, DS14mk2 FC
Disk Drive Capacities Supported 72/144/300GB FC, 250GB ATA
1 RLM module is included at no charge with SupportEdge Premium contract; otherwise, it is an optional capability.

System Specifications FAS3020 FAS3050
Active/Active
Configuration
Single
Controller
Active/Active
Configuration
Single
Controller
Max. Raw Capacity(2), (3) 50TB 50TB 84TB 84TB
Max. Number of Disk Drives 168 168 336 336
Max. Number of FC Loops 8 4 8 4
Max. Drives per FC Loop 84 84 84 84
Max. Volume Size(3) 17.6TB 17.6TB 17.6TB 17.6TB
ECC Memory 4GB 2GB 8GB 4GB
Nonvolatile Memory 1GB 512MB 1GB 512MB
Onboard GbE Ports 8 4 8 4
Onboard 2Gb Fibre Channel Ports (configurable as Storage-attached initiator or Host-attached target) 8 4 8 4
2 Max capacity is derived based on the type, size and number of the drives.
3 Max capacity and Volume size are calculated using Base10 arithmetic (i.e. 1TB=1,000,000,000 Bytes).


I/O Expandability FAS3020 FAS3050
Active/Active
Configuration
Single
Controller
Active/Active
Configuration
Single
Controller
PCI-X Expansion Slots 6 3 6 3
Optional Network Connectivity
  Quad GbE (copper) cards
  Dual GbE (copper or fiber) cards

4
6

2
3

4
6

2
3
Dual FC Disk Adapters 6 3 6 3
Dual FC, Single FC, or LVD SCSI Adapters for Tape 6 3 6 3

System Environmental
Specifications
Single Controller Configuration Active/Active
Configuration
AC Power/Current 88 to 246VAC/9.5 to 3.2A 88 to 246/19 to 6.4A
Thermal Rating 853 Btu/hr 1706 Btu/hr
Weight 34 kg (75 lb)
Fully configured
68 kg (150 lb)
Fully configured
Height 13 cm (5.12")
3U EIA
26 cm (10.6")
6U EIA
Width 44.9 cm (17.7")
Depth 61 cm (24") without cable management tray
76.2 cm (30") with cable management tray
Operating Temperature 10°C to 40°C (50°F to 104°F)
Nonoperating Temperature -40°C to 65°C (-40°F to 149°F)
Operating and Nonoperating Relative Humidity 5% to 95% relative humidity
Operating Acoustic Noise <54 dBA sound pressure (LpA) in normal operating conditions. Normal operating conditions consist of an active system operating at 22°C and at sea level.
Min. Cabinet Clearances 25.4 cm (10") in front, 30.5 cm (12") in rear
Min. Service Clearances 76.2 cm (30") in front, 76.2 cm (30") in rear
Altitude 10,000 ft maximum

Storage Subsystem Specifications
Disk Drive Storage Shelf DiskShelf14 family - DS14, DS14mk2 FC and DS14mk2AT; each w/14 low-profile slots for FC and SATA disk drives
Disk Drive Storage Shelf Interface PCI-based Fibre Channel-Arbitrated Loop (FC-AL)
DiskShelf14 Interface Dual, redundant loop resiliency circuit (LRC) or redundant electronically switched hub (ESH and ESH2) modules
Power Supply/Cooling Fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V)
AC Power/Max. Current 100 to 120 VAC/4.4A; 200 to 240 VAC/2.3A
Operating Temperature & Relative Humidity 10°C to 40°C (50°F to 104°F); 10% to 95% relative humidity, noncondensing
Nonoperating Temperature & Relative Humidity -40°C to 65°C (-40°F to 149°F); 10% to 95% relative humidity, noncondensing
Thermal Rating 1,215 Btu/hr (fully loaded shelf)
Operating Acoustic Noise 49 dBA @ 1m at 23°C
Dimensions (height/width/depth) 3U EIA (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
Weight 77 lb (35 kg) fully loaded

FAS3000 Series FC Switch Support - Tape/SAN
Vendor Model
Brocade Silkworm 2400/2800 (TapeSAN only)
Brocade Silkworm 3200/3250/3800/3850/3900/4100/12000/24000
McData ES 3016/3032
McData Intrepid 6064/6140/ED 5000
McData Sphereon 3216/3232/4500
Cisco MDS 9120, 9140, 9216A, 9216i, 9506, 9509

NetApp Systems Cabinet
Includes 2 Sets of Dual 16A, Zero U Power Distribution Units (PDUs) Accommodates 1 system controller and 13 disk shelves, or 2 system controllers and 12 disk shelves, or 14 disk shelves only
AC Power 200 to 240VAC
Current 32A total - 2 redundant sets of dual 16A cables with NEMA L6-20 or IEC 309 connectors or Australia AS/NZ53123-20; 24A total - two redundant cables with NEMA L6-30 or IEC 309 connectors
Dimensions (height/width/depth) 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
Min. Clearances 48" (122 cm) front and rear
Shipping Height 90.6" (230 cm)
Weight (empty) 275 lb (125 kg)

Regulations NetApp FAS900 Series Storage System, DiskShelf14
Filer Safety EN 60950:2002, CE, CSA 60950 and NRTL (UL) CB (all national deviations), EN60825-1:1994, IRAM, GOST-R
Disk Shelf Safety UL/C-UL; CE
Emissions FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI
Immunity EN 55024:1998

FAS3000 Series Tape Drive Support
Qualified Tape Devices Interface
Exabyte 8900 (Mammoth-1), Mammoth-2 LVD SCSI.
Mammoth-2 also supports FC
HP Ultrium (LTO) LVD SCSI
IBM 3590B, 3590E FC
IBM ULT3580-TDI (LTO) Ultrium-TDI (LTO) LVD SCSI or FC
Quantum DLT 7000 SE SCSI
Quantum DLT 8000, DLT-1, SDLT 220, SDLT 320 LVD SCSI SCSI
Seagate Ultrium (LTO) LVD SCSI
Sony AIT-1, AIT-2, AIT-3 LVD SCSI
Sony GY 8240 (DTF2) FC
STK 9840, 9840B, 9940 FC
FC = Fibre Channel; LVD = Low Voltage Differential; SE = Single-Ended; SE and LVD cannot be mixed on an adapter.


 



HomeNetApp OverviewNetApp ProductsNetApp SolutionsLiterature LibraryRequest a QuoteAbout Q AssociatesServicesPartnersQ NewsRelated LinksSite Map

Q Associates
Langley Business Court, Beedon, Newbury, Berkshire, RG20 8RY, UK.
E-mail: info@qassociates.co.uk I Tel: +44 (0)1635 248 181 I Fax: +44 (0)1635 247 616