NetApp, Network Appliance, platinum, reseller, UK  
FAS Systems
gFiler
IP SAN
NearStore
NearStore VTL
V-Series

 
V-Series family UK from Q Associates, NetApp, Network Appliance platinum reseller UK
NetApp Products - V-Series - Family Specifications
home ) netapp products ) v-series ) family specification
 
 
NetCache family UK product comparison SPEC SFS network diagram
   

Product Highlights  
Operating System Network Appliance™ Data ONTAP® 7G software
Standard Software Features Integrated automatic RAID manager, Snapshot™, Fast Boot, FlexVol™, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView®, NDMP, antivirus, LDAP
Network Protocol Support NFS V2/V3/V4 over UDP or TCP, PC NFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, HTTP 1.0, HTTP 1.1 virtual hosts, WebDAV
SAN Protocol Support Fibre Channel Protocol (FCP), iSCSI; fabric-attached and direct-attached
Data Availability Software Clustered failover, SyncMirror™, MetroCluster
Data Protection Software SnapRestore®, SnapMirror®, SnapVault®, SnapLock™ Enterprise, LockVault™ Enterprise
Data Management Software MultiStore®, SnapMover®, SnapDrive™, SnapManager® for Microsoft Exchange, SnapManager for Microsoft SQL Server, Single Mailbox Recovery, VFM™ (Virtual File Manager), SnapValidator™, FlexClone™, FlexCache
Storage Management Software DataFabric® Manager, SecureAdmin™, ApplianceWatch™ for HP OpenView, ApplianceWatch for Tivoli, HiScan Agent for HDS HiCommand(1)
Hardware Features Redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, diagnostic LED/LCD, 19" rack-mount enclosure, optional 220V 42U 19" system cabinet

1 Applicable only to HDS arrays.

 

Active/Active Specifications GF980c GF960c V3050c V3020c GF270c
Max. Raw Capacity(2) 96TB 48TB 80TB 48TB 8TB
Max. Number of LUNs 672 672 336 168 56
Storage Array LUN Size 1 to 500GB 1 to 500GB 1 to 500GB 1 to 500GB 1 to 500GB
Volumes (min./max.) 2/200 2/200 2/200 2/200 2/200
Max. Volume Size(2) 16TB 16TB 16TB 16TB 4TB
RAID Group Sizes (default/min./max.) 1/1/28 LUNs; min. 1 RAID group per volume
ECC Memory 16GB 12GB 8GB 4GB 4GB
Nonvolatile Memory 1GB 512MB 1GB 1GB 256MB
Clustered Failover-Capable Standard Standard Standard Standard Standard
Onboard 2Gb Fibre Channel Ports(3) N/A N/A 8 8 2
Onboard GbE Ports (copper) N/A N/A 8 8 4
PCI-X Expansion Slots 18 16 6 6 N/A
Dual-Port FC Disk Adapters (max./min.) 8/4 8/4 3/0 3/0 N/A
Optional Network Connectivity
Dual GbE (copper or fiber)
Single GbE (copper or fiber)
Quad GbE (copper)
SnapMirror (Fibre Channel–fiber)
IPSec Accelerator
14 max.
10 max.
14 max.
6 max.
4 max.
2 max.
12 max.
8 max.
12 max.
6 max.
4 max.
2 max.
6 max.
6 max.
N/A
4 max.
4 max.
2 max.
6 max.
6 max.
N/A
4 max.
4 max.
2 max.
N/A
Optional Dual LVD SCSI Adapter for Tape 6 max. 6 max. 6 max. 6 max. N/A
Optional Fibre Channel Adapter for Tape
Dual Fibre Channel (fiber)
Single Fibre Channel (copper)

6 max.
6 max.

6 max.
6 max.

6 max.
4 max.

6 max.
4 max.

N/A
Dual Fibre Channel for Host Attach-SAN 4 max. 4 max. 4 max. 4 max. N/A

2 1TB=1,048,576,000,000 bytes.
3 Configurable as storage-attached initiator or host-attached target

 

System Specifications GF980 GF960 V3050 V3020
Max. Raw Capacity(2) 48TB 24TB 80TB 48TB
Max. Number of LUNs 336 336 336 168
Storage Array LUN Size 1 to 500GB 1 to 500GB 1 to 500GB 1 to 500GB
Volumes (min./max.) 1/200 1/200 1/200 1/200
Max. Volume Size(2) 16TB 16TB 16TB 16TB
RAID Group Sizes (default/min./max.) 1/1/28 LUNs; min. 1 RAID group per volume
ECC Memory 8GB 6GB 4GB 2GB
Nonvolatile Memory 512MB 256MB 512MB 512MB
Clustered Failover-Capable Optional Optional Optional Optional
Onboard 2Gb Fibre Channel Ports(3) N/A N/A 4 4
Onboard GbE Ports (copper) N/A N/A 4 4
PCI-X Expansion Slots 7 7 3 3
Dual-Port FC Disk Adapters (max./min.) 4/2 4/2 3/0 3/0
Optional Network Connectivity
Dual GbE (copper or fiber)
Single GbE (copper or fiber)
Quad GbE (copper)
SnapMirror (Fibre Channel–fiber)
IPSec Accelerator
16 max.
4 max.
6 max.
3 max.
2 max.
1 max.
6 max.
4 max.
6 max.
3 max.
2 max.
1 max.
3 max.
3 max.
N/A
2 max.
2 max.
1 max.
3 max.
3 max.
N/A
2 max.
2 max.
1 max.
Optional Dual LVD SCSI Adapter for Tape 3 max. 3 max. 3 max. 3 max.
Optional Fibre Channel Adapter for Tape
Dual Fibre Channel (fiber)
Single Fibre Channel (copper)

3 max.
3 max.

3 max.
3 max.

3 max.
2 max.

3 max.
2 max.
Dual Fibre Channel for Host Attach-SAN 2 max. 2 max. 2 max. 2 max.

2 1TB=1,048,576,000,000 bytes.
3 Configurable as storage-attached initiator or host-attached target

 

Storage Subsystem Specification  
Storage Interface Data/Rate PCI-based Fibre Channel Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 2Gb/sec
Storage Arrays Hitachi TagmaStore Universal Storage Platform (USP)
Hitachi Lightning 9900V (9980V, 9970V)
Hitachi Lightning 9900 (9960, 9910)
Hitachi Thunder 9500V (9585V, 9570V)
Hitachi SANRISE 9900V and 9500V series
Hitachi Sun StorEdge 9990, 9980, 9970, 9960, 9910
IBM TotalStorage Enterprise Storage Server (ESS) Model 800
Turbo, 800, 750
IBM TotalStorage DS4000 (DS4500, DS4400, DS4300 Turbo,
DS4300, DS4100)
HP StorageWorks XP Arrays (XP12000, XP1024, XP512, XP128,
XP48)

 

Storage Array SAN Connectivity  
Vendor Model
Brocade Silkworm 3200, 3250, 3800, 3850, 3900, 12000
Cisco MDS 9120, 9140, 9216, 9506, 9509
McDATA Sphereon 32XX, 4300, 4500
Intrepid 6064, 6140

 

System Environmental Specifications GF980c, GF960c GF980, GF960
AC Power/Max. Current 100 to 240VAC, 7.6A (typical)/
24A (max.) @ 100VAC
100 to 240VAC, 3.8A (typical)/
12A (max.) at 100VAC
Thermal Rating 2,252 Btu/hr 1,126 Btu/hr
Dimensions
Weight
Height

214 lb (97 kg)
20.8" (52.8 cm)

106 lb (48 kg)
10.3" (26.2 cm)
Width
Depth
19" IEC rack-compliant (17", 43.2 cm)
22" (56 cm) without cable management bracket; 25" (63.5 cm) with cable management bracket
Operating Temperature & Relative Humidity 10°C to 40°C (50°F to 104°F) <2,100 m (<7,000') elevation;
10°C to 35°C (50°F to 95°F) <3,000 m (<10,000') elevation;
20% to 80% relative humidity, noncondensing
Nonoperating Temperature & Relative Humidity -20°C to 65°C (-4°F to 149°F); 8% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise <52 dBa @ 1 m, <66 dBa @ 1 m high temp./degraded mode
Min. Cabinet Clearances 1.5" (3.8 cm) for bezel; 3" (7.6 cm) for cable radius
Min. Service Clearances 9" (23 cm) front; 30" (76 cm) rear

 

System Environmental Specifications V3050c, V3020c V3050, V3020
AC Power/Max. Current 88 to 246VAC/19 to 6.4A 88 to 246VAC/9.5 to 3.2A
Thermal Rating 1706 Btu/hr 853 Btu/hr
Dimensions
Weight
Height

150 lb (68 kg)
10.6" (26 cm), 6U EIA

75 lb (34 kg)
5.12" (13 cm), 3U EIA
Width
Depth
17.7" (44.9 cm)
24" (61 cm) without cable management tray
30" (76.2 cm) with cable management tray
Operating Temperature & Relative Humidity 10°C to 40°C (50°F to 104°F); <3,000 m (<10,000') elevation;
5% to 95% relative humidity
Nonoperating Temperature & Relative Humidity -40°C to 65°C (-40°F to 149°F); 5% to 95% relative humidity
Operating Acoustic Noise <54 dBA sound pressure (LpA) in normal operating conditions.
Normal operating conditions consist of an active system operating at 22°C and at sea level.
Min. Cabinet Clearances 10" (25.4 cm) in front, 12" (30.5 cm) in rear
Min. Service Clearances 30" (76.2 cm) in front, 30" (76.2 cm) in rear

 

System Environmental Specifications GF270c
AC Power/Max. Current 100 to 120VAC, 3.45A; 200 to 240VAC, 1.90A
Thermal Rating 1,215 Btu/hr
Dimensions
Weight
Height
Width
Depth

78.8 lb (35.8 kg)
5.25" (13.3 cm)
19" EIA rack-compliant (17.6", 44.7 cm)
20" (50.8 cm)
Operating Temperature & Relative Humidity 10°C to 40°C (50°F to 104°F); 20% to 80% relative humidity, noncondensing
Nonoperating Temperature & Relative Humidity -40°C to 65°C (-40°F to 149°F); 8% to 95% relative humidity, noncondensing
Operating Acoustic Noise <60 dBa @ 1 m at 20°C
Min. Cabinet Clearances 3" (7.6 cm) rear for cable radius
Min. Service Clearances 9" (23 cm) front; 30" (76.2 cm) rear

 

Regulations  
Filer Safety EN 60950:2000, CE, CSA 60950-00, NRTL (UL60950-2000), CB IEC 60950 Ed. 3 (all national deviations), EN60825-1:1994+A11
Disk Shelf Safety UL/C-UL; CE
Emissions FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI
Immunity EN 55024:1998

 

V-Series TapeSAN Solutions  
Model Backup Solutions
GF270c Host-based backup
V30XX; GF9XX Direct-attached or SAN-attached(4), (5)
Supported tape drives: www.netapp.com/solutions/data_protection_devices.html
Tape drive interface: LVD FC, LVD SCSI, FC, SE SCSI(6)

4 V-Series FC Tape SAN backup solution: www.netapp.com/osn/info/config.html.
5 V-Series GBE Tape SAN backup solution: www.netapp.com/osn/info/config_gbe.html.
6 FC = Fibre Channel; LVD = Low Voltage Differential; SE = Single-Ended; SE and LVD cannot be mixed on an adapter.

 

NetCache family UK product comparison SPEC SFS network diagram
   


HomeNetApp OverviewNetApp ProductsNetApp SolutionsLiterature LibraryRequest a QuoteAbout Q AssociatesServicesPartnersQ NewsRelated LinksSite Map

Q Associates
Langley Business Court, Beedon, Newbury, Berkshire, RG20 8RY, UK.
E-mail: info@qassociates.co.uk I Tel: +44 (0)1635 248 181 I Fax: +44 (0)1635 247 616