| Product Highlights |
|
| Operating System |
Network Appliance™ Data ONTAP® 7G software |
| Standard Software Features |
Integrated automatic RAID manager, Snapshot™, Fast Boot, FlexVol™, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView®, NDMP, antivirus, LDAP |
| Network Protocol Support |
NFS V2/V3/V4 over UDP or TCP, PC NFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, HTTP 1.0, HTTP 1.1 virtual hosts, WebDAV |
| SAN Protocol Support |
Fibre Channel Protocol (FCP), iSCSI; fabric-attached and direct-attached |
| Data Availability Software |
Clustered failover, SyncMirror™, MetroCluster |
| Data Protection Software |
SnapRestore®, SnapMirror®, SnapVault®, SnapLock™ Enterprise, LockVault™ Enterprise |
| Data Management Software |
MultiStore®, SnapMover®, SnapDrive™, SnapManager® for Microsoft Exchange, SnapManager for Microsoft SQL Server, Single Mailbox Recovery, VFM™ (Virtual File Manager), SnapValidator™, FlexClone™, FlexCache |
| Storage Management Software |
DataFabric® Manager, SecureAdmin™, ApplianceWatch™ for HP OpenView, ApplianceWatch for Tivoli, HiScan Agent for HDS HiCommand(1) |
| Hardware Features |
Redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, diagnostic LED/LCD, 19" rack-mount enclosure, optional 220V 42U 19" system cabinet |
1 Applicable only to HDS arrays.
| Active/Active Specifications |
GF980c |
GF960c |
V3050c |
V3020c |
GF270c |
| Max. Raw Capacity(2) |
96TB |
48TB |
80TB |
48TB |
8TB |
| Max. Number of LUNs |
672 |
672 |
336 |
168 |
56 |
| Storage Array LUN Size |
1 to 500GB |
1 to 500GB |
1 to 500GB |
1 to 500GB |
1 to 500GB |
| Volumes (min./max.) |
2/200 |
2/200 |
2/200 |
2/200 |
2/200 |
| Max. Volume Size(2) |
16TB |
16TB |
16TB |
16TB |
4TB |
| RAID Group Sizes (default/min./max.) |
1/1/28 LUNs; min. 1 RAID group per volume |
| ECC Memory |
16GB |
12GB |
8GB |
4GB |
4GB |
| Nonvolatile Memory |
1GB |
512MB |
1GB |
1GB |
256MB |
| Clustered Failover-Capable |
Standard |
Standard |
Standard |
Standard |
Standard |
| Onboard 2Gb Fibre Channel Ports(3) |
N/A |
N/A |
8 |
8 |
2 |
| Onboard GbE Ports (copper) |
N/A |
N/A |
8 |
8 |
4 |
| PCI-X Expansion Slots |
18 |
16 |
6 |
6 |
N/A |
| Dual-Port FC Disk Adapters (max./min.) |
8/4 |
8/4 |
3/0 |
3/0 |
N/A |
Optional Network Connectivity
Dual GbE (copper or fiber)
Single GbE (copper or fiber)
Quad GbE (copper)
SnapMirror (Fibre Channel–fiber)
IPSec Accelerator |
14 max.
10 max.
14 max.
6 max.
4 max.
2 max. |
12 max.
8 max.
12 max.
6 max.
4 max.
2 max. |
6 max.
6 max.
N/A
4 max.
4 max.
2 max. |
6 max.
6 max.
N/A
4 max.
4 max.
2 max. |
N/A |
| Optional Dual LVD SCSI Adapter for Tape |
6 max. |
6 max. |
6 max. |
6 max. |
N/A |
Optional Fibre Channel Adapter for Tape
Dual Fibre Channel (fiber)
Single Fibre Channel (copper) |
6 max.
6 max. |
6 max.
6 max. |
6 max.
4 max. |
6 max.
4 max. |
N/A
|
| Dual Fibre Channel for Host Attach-SAN |
4 max. |
4 max. |
4 max. |
4 max. |
N/A |
2 1TB=1,048,576,000,000 bytes.
3 Configurable as storage-attached initiator or host-attached target
| System Specifications |
GF980 |
GF960 |
V3050 |
V3020 |
| Max. Raw Capacity(2) |
48TB |
24TB |
80TB |
48TB |
| Max. Number of LUNs |
336 |
336 |
336 |
168 |
| Storage Array LUN Size |
1 to 500GB |
1 to 500GB |
1 to 500GB |
1 to 500GB |
| Volumes (min./max.) |
1/200 |
1/200 |
1/200 |
1/200 |
| Max. Volume Size(2) |
16TB |
16TB |
16TB |
16TB |
| RAID Group Sizes (default/min./max.) |
1/1/28 LUNs; min. 1 RAID group per volume |
| ECC Memory |
8GB |
6GB |
4GB |
2GB |
| Nonvolatile Memory |
512MB |
256MB |
512MB |
512MB |
| Clustered Failover-Capable |
Optional |
Optional |
Optional |
Optional |
| Onboard 2Gb Fibre Channel Ports(3) |
N/A |
N/A |
4 |
4 |
| Onboard GbE Ports (copper) |
N/A |
N/A |
4 |
4 |
| PCI-X Expansion Slots |
7 |
7 |
3 |
3 |
| Dual-Port FC Disk Adapters (max./min.) |
4/2 |
4/2 |
3/0 |
3/0 |
Optional Network Connectivity
Dual GbE (copper or fiber)
Single GbE (copper or fiber)
Quad GbE (copper)
SnapMirror (Fibre Channel–fiber)
IPSec Accelerator |
16 max.
4 max.
6 max.
3 max.
2 max.
1 max. |
6 max.
4 max.
6 max.
3 max.
2 max.
1 max. |
3 max.
3 max.
N/A
2 max.
2 max.
1 max. |
3 max.
3 max.
N/A
2 max.
2 max.
1 max. |
| Optional Dual LVD SCSI Adapter for Tape |
3 max. |
3 max. |
3 max. |
3 max. |
Optional Fibre Channel Adapter for Tape
Dual Fibre Channel (fiber)
Single Fibre Channel (copper) |
3 max.
3 max. |
3 max.
3 max. |
3 max.
2 max. |
3 max.
2 max. |
| Dual Fibre Channel for Host Attach-SAN |
2 max. |
2 max. |
2 max. |
2 max. |
2 1TB=1,048,576,000,000 bytes.
3 Configurable as storage-attached initiator or host-attached target
| Storage Subsystem Specification |
|
| Storage Interface Data/Rate |
PCI-based Fibre Channel Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 2Gb/sec |
| Storage Arrays |
Hitachi TagmaStore Universal Storage Platform (USP)
Hitachi Lightning 9900V (9980V, 9970V)
Hitachi Lightning 9900 (9960, 9910)
Hitachi Thunder 9500V (9585V, 9570V)
Hitachi SANRISE 9900V and 9500V series
Hitachi Sun StorEdge 9990, 9980, 9970, 9960, 9910
IBM TotalStorage Enterprise Storage Server (ESS) Model 800
Turbo, 800, 750
IBM TotalStorage DS4000 (DS4500, DS4400, DS4300 Turbo,
DS4300, DS4100)
HP StorageWorks XP Arrays (XP12000, XP1024, XP512, XP128,
XP48) |
| Storage Array SAN Connectivity |
|
| Vendor |
Model |
| Brocade |
Silkworm 3200, 3250, 3800, 3850, 3900, 12000 |
| Cisco |
MDS 9120, 9140, 9216, 9506, 9509 |
| McDATA |
Sphereon 32XX, 4300, 4500
Intrepid 6064, 6140 |
| System Environmental
Specifications |
GF980c, GF960c |
GF980, GF960 |
| AC Power/Max. Current |
100 to 240VAC, 7.6A (typical)/
24A (max.) @ 100VAC |
100 to 240VAC, 3.8A (typical)/
12A (max.) at 100VAC |
| Thermal Rating |
2,252 Btu/hr |
1,126 Btu/hr |
Dimensions
Weight
Height |
214 lb (97 kg)
20.8" (52.8 cm) |
106 lb (48 kg)
10.3" (26.2 cm) |
Width
Depth |
19" IEC rack-compliant (17", 43.2 cm)
22" (56 cm) without cable management bracket; 25" (63.5 cm) with cable management bracket |
| Operating Temperature & Relative Humidity |
10°C to 40°C (50°F to 104°F) <2,100 m (<7,000') elevation;
10°C to 35°C (50°F to 95°F) <3,000 m (<10,000') elevation;
20% to 80% relative humidity, noncondensing |
| Nonoperating Temperature & Relative Humidity |
-20°C to 65°C (-4°F to 149°F); 8% to 95% relative humidity, noncondensing, in original container |
| Operating Acoustic Noise |
<52 dBa @ 1 m, <66 dBa @ 1 m high temp./degraded mode |
| Min. Cabinet Clearances |
1.5" (3.8 cm) for bezel; 3" (7.6 cm) for cable radius |
| Min. Service Clearances |
9" (23 cm) front; 30" (76 cm) rear |
| System Environmental
Specifications |
V3050c, V3020c |
V3050, V3020 |
| AC Power/Max. Current |
88 to 246VAC/19 to 6.4A |
88 to 246VAC/9.5 to 3.2A |
| Thermal Rating |
1706 Btu/hr |
853 Btu/hr |
Dimensions
Weight
Height |
150 lb (68 kg)
10.6" (26 cm), 6U EIA |
75 lb (34 kg)
5.12" (13 cm), 3U EIA |
Width
Depth |
17.7" (44.9 cm)
24" (61 cm) without cable management tray
30" (76.2 cm) with cable management tray |
| Operating Temperature & Relative Humidity |
10°C to 40°C (50°F to 104°F); <3,000 m (<10,000') elevation;
5% to 95% relative humidity |
| Nonoperating Temperature & Relative Humidity |
-40°C to 65°C (-40°F to 149°F); 5% to 95% relative humidity |
| Operating Acoustic Noise |
<54 dBA sound pressure (LpA) in normal operating conditions.
Normal operating conditions consist of an active system operating at 22°C and at sea level. |
| Min. Cabinet Clearances |
10" (25.4 cm) in front, 12" (30.5 cm) in rear |
| Min. Service Clearances |
30" (76.2 cm) in front, 30" (76.2 cm) in rear |
| System Environmental Specifications |
GF270c |
| AC Power/Max. Current |
100 to 120VAC, 3.45A; 200 to 240VAC, 1.90A |
| Thermal Rating |
1,215 Btu/hr |
Dimensions
Weight
Height
Width
Depth |
78.8 lb (35.8 kg)
5.25" (13.3 cm)
19" EIA rack-compliant (17.6", 44.7 cm)
20" (50.8 cm) |
| Operating Temperature & Relative Humidity |
10°C to 40°C (50°F to 104°F); 20% to 80% relative humidity, noncondensing |
| Nonoperating Temperature & Relative Humidity |
-40°C to 65°C (-40°F to 149°F); 8% to 95% relative humidity, noncondensing |
| Operating Acoustic Noise |
<60 dBa @ 1 m at 20°C |
| Min. Cabinet Clearances |
3" (7.6 cm) rear for cable radius |
| Min. Service Clearances |
9" (23 cm) front; 30" (76.2 cm) rear |
| Regulations |
|
| Filer Safety |
EN 60950:2000, CE, CSA 60950-00, NRTL (UL60950-2000), CB IEC 60950 Ed. 3 (all national deviations), EN60825-1:1994+A11 |
| Disk Shelf Safety |
UL/C-UL; CE |
| Emissions |
FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI |
| Immunity |
EN 55024:1998 |
4 V-Series FC Tape SAN backup solution: www.netapp.com/osn/info/config.html.
5 V-Series GBE Tape SAN backup solution: www.netapp.com/osn/info/config_gbe.html.
6 FC = Fibre Channel; LVD = Low Voltage Differential; SE = Single-Ended; SE and LVD cannot be mixed on an adapter.
|